- FEFA INDUSTRIAL UPS IGTX3 5~50KVA 1:1
- FEFA INDUSTRIAL UPS IGTX3 5~50KVA 3:1
- FEFA INDUSTRIAL UPS IGTX3 5~80KVA 3:3
- FEFA INDUSTRIAL UPS IGTX3 100~800KVA 3:3
Higher ratings available upon request
Features
- True Online technology: Load is supplied with power without interruption regardless of the UPS operating mode, transfer between UPS modes without interruption.
- Isolation Transformer in output (available input/bypass transformer upon request)
- Full DSP control: Full DSP Control avoids the risks caused by analog devices failure and makes the control system more stable and reliable
- Wide input voltage: The range of AC input voltage is (380Vac I 400Vac I 415Vac, 480Vac) (-25% / +20%), minimizing the chance of transferring to battery mode, thereby allowing battery to serve longer life.
- Very high crest factor (3:1 higher values available upon request)
- Several Mechanical options:
- Top/bottom cable entry
- Protection up to IP 52
- Air filters at air inlet
- 100% redundant ventilation
- Seismic design
- Space heaters
- Panel lighting
- Cabinet color as required
- Ambient temperature maximum +55 °C
- Allowable altitude up to 4,000m above sea level
- N+X parallel redundant: N+X parallel redundant design, up to 4 units available, makes the configuration more flexible and reliable. In case of parallel unit failure, the failed unit will disconnect from load, other units will keep supplying power to load based on equal sharing without interruption of supply. It is easy to configure the parallel system just by connecting the parallel cables and doing corresponding settings.
- Non-fixed Master-Slave relationship: Among several UPS in parallel, the unit startup first is Master UPS, the others are Slave. The master and slave may be exchanged.
- Strong overload capability:
- 110% overload for 60 minutes.
- 125% overload for 10 minutes
- 150% overload for 1 minute
- 200% overload for 0.1 second.
- Power walk in: Specially designed power walk in function, in which rectifier of each unit in parallel system will be turned on in sequence at intervals to avoid the sudden load impact on the generator, thereby reducing the capacity oversizing of the generator required.
- Multi-protection: Short circuit ( with electronic protection) , overload, over temperature, min/max battery voltage, min/max input voltage, min/max inverter voltage, synchronism
- User-friendly network management: English/French LCD and LED mimic diagram: real time operation parameters and status
- RS232 & RS485 communication ports: for local monitor with corresponding software, and CAN protocol is optional.
- SNMP adapter (optional): for remote monitor through network
- Dry contacts for additional monitoring:
- UPS on Inverter
- Mains input failure
- Battery low voltage alarm (optional)
- UPS fault
- UPS alarm
- UPS on battery
- UPS on bypass (optional)